Black Acetal Fittings – PM Range
– Specifications
All our technical information for our Black Acetal PM Range of products can be found here.
Black Acetal Fittings – PM Range
Style and Description
For Liquids & Inert Gases
The PM Range of metric size fittings are manufactured in black acetal copolymer with food grade nitrile O-Rings. Being especially produced for foodstuffs and potable liquids, they are equally suitable for air and inert gases and can therefore be used on N2/CO2 mixed gas dispense lines and pneumatic applications and vacuum (ensure products are installed in accordance with local codes of practice).
Media / Application
✓ Air / Vacuum
✓ Potable Liquids
Sizes – Outside Diameter (OD) Pipe
- 4mm – 8mm
- 10mm – 22mm
Maximum Working Pressure (kPa)
Temperature | Pressure | |
---|---|---|
AIR / VACUUM | 4mm – 8mm | 10mm – 22mm |
-20°C | 1600kPa | 1000kPa |
+1°C | 1600kPa | 1000kPa |
+20°C | 1600kPa | 1000kPa |
+65°C* | 1000kPa | 700kPa |
Temperature | Pressure | |
---|---|---|
POTABLE LIQUIDS | 4mm – 8mm | 10mm – 22mm |
-20°C | DO NOT FREEZE | |
+1°C | 1600kPa | 1000kPa |
+20°C | 1600kPa | 1000kPa |
+65°C* | 1000kPa | 700kPa |
*NOT to exceed maximum temperature
Installation Instructions

Step 1
Prepare the Pipe
Ensure the pipe is free of score marks. Cut the pipe square. We recommend the use of JG Pipe Cutters.
To prevent damage to the O-Ring, remove all burrs and sharp edges. When connecting Speedfit Pipe, use a Speedfit Pipe Insert. A twisting motion will aid insertion. The insert should only be used with Speedfit Pipe.

Step 2
Push Up to Pipe Stop
Push the pipe into the fitting, to the pipe stop.

Step 3
Pull to Secure
Pull on the pipe to check it is secure. Test the system before use.
Don’t forget to push the pipe fully into the fitting, past both the collet (gripper) and the O-Ring.
Troubleshooting

Pipe Stop Distances
Stops are located at the following distances from the end of the fitting:
Size | Stop Distances |
---|---|
10mm | 20mm |
15mm | 30mm |
22mm | 35mm |
28mm | 44mm |

Check Pipe Grip & Depth
Make sure to push the pipe fully into the fitting, past both the collet (gripper) and the O-Ring.
Fitting may be gripped but not sealed if pipe is not fully inserted.

Do not use a hacksaw to cut the pipe.
This will leave unwanted burrs on the end of the pipe.

Do not use damage or scored pipe.
Score marks can cause leaks past the O-Ring.


How to Disconnect

Quick Disconnect
Push in Collet and Remove Tube
To disconnect, ensure the system is depressurized, push the collet square against the fitting. With the collet held in this position the tube can be removed.
Collet Covers & Clips

Collet Cover & Clip Applications
Use a collet cover or collet clip to provide added security against pipe disconnection, e.g. the fitting coming into contact with rigid surfaces and behind dry-lining walls.
Collet covers for use with standard Speedfit fittings, are available in white, red or blue to allow colour coding of pipes.

White & Grey Collet Clips
White or grey collet clips are used with standard fittings to prevent accidental pipe disconnection.

Red & Blue Collet Clips
Red or blue collet clips provide colour coding of pipe on Twist & Lock fittings. They are not designed to prevent accidental release, and should be fitted when the fitting is in the locked position.