Insulated floor panel including return bends for timber floor installations. For joist and battened floors
JG Underfloor underfit board is a low-profile underfloor heating (UFH) pipe fixing system designed for existing timber suspended or floating floor structures. Ideal for retrofit projects, the pipe fixing system provides no height build up and is suitable for ground and first floor level applications.
15mm pipe is easily installed into a grooved foil-faced panel over an existing floor, either between battens or under the floor between joists. Maximum pipe circuit length is 100m with a recommended flow temperature of 50-60ºC.
Features and benefits
- Existing floor pipe fixing system
- Lightweight insulated panel
- Grooved foil-faced panel with 200mm centres
- Low height build up
- Medium to low heat output and response (approx. 50-60w/m2)
- Ideal for rooms of all sizes and shapes
- Suitable for underfloor heating applications only